Work it out in three steps: find the R-value your climate zone calls for, measure the area in square feet, then use the chart on the bag or package to convert that into bags or batts. ENERGY STAR recommends R-49 to R-60 for an uninsulated attic in most of the US (R-30 in the hottest zone). Blown-in cellulose needs about 13–15 in of depth for R-49, and loose-fill fiberglass about 18–22 in.

Step 1: Find the R-value you need
R-value measures how well insulation resists heat flow. Higher is better, and the right target depends on your climate zone. ENERGY STAR's recommendations for existing wood-framed homes, based on the 2021 IECC, are:
| Climate zone | Uninsulated attic | Attic with 3–4 in already | Floor |
|---|---|---|---|
| 1 (south Florida, Hawaii) | R-30 | R-25 | R-13 |
| 2 | R-49 | R-38 | R-13 |
| 3 | R-49 | R-38 | R-19 |
| 4A and 4B | R-60 | R-49 | R-19 |
| 4C, 5 and 6 | R-60 | R-49 | R-30 |
| 7 and 8 | R-60 | R-49 | R-38 |
Source: ENERGY STAR, Recommended Home Insulation R-Values, which also has a climate zone map. New construction must meet the energy code your town has adopted, so check with your building department before you build or remodel.
Walls are limited by the stud depth. A 2×4 wall is 3½ in deep and usually gets R-13 or R-15 batts; a 2×6 wall is 5½ in deep and usually gets R-19 or R-21. For more, ENERGY STAR suggests adding insulated sheathing under new siding (R-5 in zone 3, R-10 in zones 4–8 when the cavities are already insulated).
Step 2: Measure the area
- Attic floor: length × width of the house footprint, not counting garages or porches with their own roof. A 30 × 40 ft house has a 1,200 sq ft attic.
- Walls: wall length × height for each exterior wall, minus large windows and doors. Don't subtract outlets.
- Floors over crawlspaces or garages: length × width of the floor above.
The square footage calculator handles L-shapes and odd layouts, and how to measure a room walks through wall area step by step.
Step 3a: Blown-in insulation depth and bags
For loose-fill (blown-in) insulation, R-value comes from depth. Settled R-value per inch runs about 3.2–3.8 for cellulose and 2.2–2.7 for fiberglass (DOE / Building America Solution Center). Divide the target R-value by those figures to get the depth:
Settled depth, upper end of each range
| Target | Cellulose (R-3.2 to 3.8/in) | Loose-fill fiberglass (R-2.2 to 2.7/in) |
|---|---|---|
| R-30 | 7.9–9.4 in | 11.1–13.6 in |
| R-38 | 10.0–11.9 in | 14.1–17.3 in |
| R-49 | 12.9–15.3 in | 18.1–22.3 in |
| R-60 | 15.8–18.8 in | 22.2–27.3 in |
These are settled depths. Cellulose settles about 10–20% over time and loose-fill fiberglass about 2–4%, so blow it in to the "initial installed thickness" printed on the bag, not the settled number.
How many bags? Every bag has a coverage chart that lists, for each R-value, the square feet one bag covers, the minimum thickness and the bags per 1,000 sq ft. Bags differ by brand and product, so always use the chart on the bag you buy:
Bags = attic area ÷ sq ft per bag at your target R-value (round up)
Worked example: a 1,200 sq ft attic in zone 5 with no insulation needs R-60. With cellulose that's about 15.8–18.8 in settled. If the bag chart says one bag covers 25 sq ft at R-60 (an illustration; read your own bag), you need 1,200 ÷ 25 = 48 bags. Some home centers lend a blowing machine when you buy the insulation there, so ask before you rent one.
Adding to existing insulation
Measure the depth of what's there in a few spots. Three to four inches of old loose-fill fiberglass is only about R-8 to R-11 (3.5 in × 2.2 = R-7.7, 4 in × 2.7 = R-10.8). Subtract that from your target and blow in enough to make up the difference. In zone 4, topping a 3–4 in layer up to R-49 means adding roughly R-38 to R-41, or about 10–13 in of cellulose. Don't install over insulation that's wet, moldy or looks like vermiculite (grey-brown, pebbly granules), which may contain asbestos; have that tested first.
Step 3b: Batts and rolls for walls and floors
Batts are sized to fit between framing: 15 in wide for studs 16 in on center and 23 in wide for 24 in on center (see how far apart wall studs are). Packages list the square feet they cover, which already accounts for the framing, so:
Packages = wall area ÷ sq ft per package, plus 5–10% for cuts
Worked example: a 12 × 14 ft bedroom with two exterior walls (12 + 14 = 26 ft) and 8 ft ceilings has 208 sq ft of exterior wall. Take off a 3 × 5 ft window (15 sq ft) and you have 193 sq ft. Add 10% and buy enough R-13 or R-15 for about 212 sq ft. Use the stud calculator if you're framing the wall too, and the drywall calculator for the sheets that go over it.
Common mistakes
- Compressing batts. Stuffing an R-19 batt into a 2×4 wall squashes it and lowers its R-value. Match the batt to the cavity depth.
- Blowing to the settled depth. Use the initial installed thickness from the bag, or cellulose will settle below your target.
- Covering soffit vents. Fit baffles at the eaves so blown insulation doesn't block attic airflow.
- Skipping air sealing. Seal gaps around plumbing, wiring, chimneys and the attic hatch before you insulate. Insulation doesn't stop air leaks.
- Burying hazards. Keep insulation away from chimneys, flues and recessed lights unless they're rated for contact (IC-rated), and follow clearance rules for each.
Better insulation also lowers heating and cooling loads. If you're replacing equipment, see how many BTU per square foot you need and use the BTU calculator as a starting point.
Frequently asked questions
How much insulation do I need?
Find the R-value your climate zone calls for, measure the area in square feet, then divide by the coverage per bag or package at that R-value from the manufacturer's chart and round up. ENERGY STAR recommends R-49 to R-60 for an uninsulated attic in most of the US.
How much insulation do I need in my attic?
For an uninsulated attic ENERGY STAR recommends R-30 in zone 1, R-49 in zones 2–3 and R-60 in zones 4–8. If you already have 3–4 inches, the targets are R-25, R-38 and R-49.
How deep should blown-in insulation be?
Divide the R-value you want by the R-value per inch. For R-49 that's about 13–15 inches of settled cellulose or 18–22 inches of loose-fill fiberglass. Blow it to the initial thickness on the bag so it still meets the target after settling.
How many bags of blown-in insulation do I need?
Divide your attic area by the square feet one bag covers at your target R-value, as listed on the bag's coverage chart, and round up. Coverage varies by brand and product.
What R-value insulation do I need for walls?
Most 2×4 walls get R-13 or R-15 batts and 2×6 walls get R-19 or R-21. In colder zones ENERGY STAR suggests adding insulated sheathing under new siding.
How much does 3 to 4 inches of old attic insulation add?
Loose-fill fiberglass at 3–4 inches is only about R-8 to R-11, so most older attics need another 10 inches or more to reach R-49.
Sources
- ENERGY STAR: Recommended Home Insulation R-Values (retrofit levels by climate zone, based on the 2021 IECC)
- Building America Solution Center (PNNL): Loose-fill insulation (R-value per inch, settling, citing DOE)
- University of Missouri Extension: Home Insulation Choices (batt and loose-fill R-values)